Occupational Radiation Exposure in Diagnostic and Interventional Radiology: A Comprehensive Review

Authors

DOI:

https://doi.org/10.63187/ampas.52

Keywords:

Fluoroscopy, Occupational radiation exposure, Interventional radiology, Radiation protection, Dose optimisation, Scatter radiation, Lens dose

Abstract

Abstract

Introduction: The use of ionising radiation in medical imaging and interventional procedures has been steadily increasing for both diagnostic and therapeutic purposes. Fluoroscopy, which provides real-time imaging, is widely employed in diagnostic and interventional radiology. However, fluoroscopy-guided interventional procedures (FGIPs) represent one of the highest occupational radiation exposure risks for healthcare personnel. This review aims to evaluate the radiation doses received by medical staff in fluoroscopy rooms and to discuss protective strategies based on current literature.

Materials and Methods: A comprehensive literature review was conducted by analysing studies published between 2000 and 2025 in PubMed, Scopus, and Google Scholar databases using the keywords “fluoroscopy,” “radiation exposure,” “occupational dose,” “interventional radiology,” and “radiation protection.” Studies reporting staff dose measurements, effects of procedure type, protective equipment performance, and scatter geometry were reviewed. Findings were compared with international reference limits recommended by the ICRP and UNSCEAR.

Results: Most reported annual effective doses among fluoroscopy personnel remained within regulatory limits; however, up to 15% of interventional radiology staff exceeded the revised 20 mSv/year lens dose limit. The highest exposures occurred at the hands and eye lenses of operators. Proper use of lead glasses and ceiling-suspended shields reduced radiation by 60–98%. Dose optimisation through low-dose modes, Digital Subtraction Angiography (DSA) parameter adjustment, and real-time feedback systems provided further reduction in occupational exposure.

Conclusion: Fluoroscopy-guided interventions continue to pose a significant occupational hazard. Minimising operator dose requires not only effective shielding and equipment optimisation but also the adoption of a proactive safety culture supported by continuous feedback, proper dosimetry, and geometry-aware procedural awareness.

Keywords: Fluoroscopy, Occupational radiation exposure, Interventional radiology, Radiation protection, Dose optimisation, Scatter radiation, Lens dose.

References

References:

Milder, C. M., Borrego, D., Preston, D. L., Villoing, D., Kwon, T. E., Miller, D. L., et al. (2024). Occupational Radiation Dose Trends in US Radiologic Technologists Assisting with Fluoroscopically Guided Interventional Procedures, 1980–2020. Journal of Vascular and Interventional Radiology, 35(7), 1057-1065.

Dorman, T., Drever, B., Plumridge, S., Gregory, K., Cooper, M., Roderick, A., et al. (2023). Radiation dose to staff from medical X-ray scatter in the orthopaedic theatre. European Journal of Orthopaedic Surgery & Traumatology, 33(7), 3059-3065.

Mori, Y., Isobe, T., Ide, Y., Uematsu, S., Tomita, T., Nagai, Y., et al. (2024). Visualization of spatial dose distribution for effective radiation protection education in interventional radiology: obtaining high-accuracy spatial doses. Physical and Engineering Sciences in Medicine, 47(4), 1665-1676.

Daioku, T., Oishi, F., Kobayashi, M., Arakawa, N., & Ejiri, H. (2025). Measuring and visualizing scattered x-rays using red–green–blue (RGB) heat maps during extracorporeal membrane oxygenation in the intensive care unit. BMC Research Notes, 18(1), 220.

Vano, E., Fernandez-Soto, J. M., Ten, J. I., & Sanchez Casanueva, R. M. (2023). Occupational and patient doses for interventional radiology integrated into a dose management system. The British Journal of Radiology, 96(1143), 20220607.

R Rehani, M. M., Ciraj-Bjelac, O., Al-Naemi, H. M., Al-Suwaidi, J. S., El-Nachef, L., Khosravi, H. R., et al. (2012). Radiation protection of patients in diagnostic and interventional radiology in Asian countries: impact of an IAEA project. European journal of radiology, 81(10), e982-e989.

Balter, S., Rosenstein, M., Miller, D. L., Schueler, B., & Spelic, D. (2011). Patient radiation dose audits for fluoroscopically guided interventional procedures. Medical physics, 38(3), 1611-1618.

Joemai, R. M., Zweers, D., Obermann, W. R., & Geleijns, J. (2009). Assessment of patient and occupational dose in established and new applications of MDCT fluoroscopy. American Journal of Roentgenology, 192(4), 881-886.

Kobayashi, T., & Hirshfeld Jr, J. W. (2017). Radiation exposure in cardiac catheterization: operator behavior matters. Circulation: Cardiovascular Interventions, 10(8), e005689.

Borrego, D., Kitahara, C. M., Balter, S., & Yoder, C. (2020). Occupational doses to medical staff performing or assisting with fluoroscopically guided interventional procedures. Radiology, 294(2), 353-359.

Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., Macvittie, T. J., et al. (2012). ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs—threshold doses for tissue reactions in a radiation protection context. Annals of the ICRP, 41(1-2), 1-322.

Haga, Y., Chida, K., Kaga, Y., Sota, M., Meguro, T., & Zuguchi, M. (2017). Occupational eye dose in interventional cardiology procedures. Scientific reports, 7(1), 569.

Rehani, M. M., Miller, D. L., & Baliyan, V. (2021). High-dose fluoroscopically guided procedures in patients: radiation management recommendations for interventionalists. CardioVascular and Interventional Radiology, 44(6), 849-856.

Lopez, P. D. (2024). Fluoroscopy history, evolution, and technological advancements: A narrative review. Journal of Medical Imaging and Radiation Sciences, 55(2), 347-353.

Mussmann, B., Larsen, T. R., Godballe, M., Abdi, A. J., Kantsø, A., Jakobsen, A. R., et al. (2024). Radiation dose to multidisciplinary staff members during complex interventional procedures. Radiography, 30(2), 512-516.

Krompaß, K., Mutschler, M., Grunz, J. P., Thurner, A., Bley, T. A., Voelker, W., et al. (2025). Real-time dosimetry in interventional radiology–comparing the occupational radiation exposure in fluoroscopy-guided lower extremity and abdominal procedures. European Radiology, 35(10), 6575-6582.

Zeng, X., Wang, H., & Chen, G. (2025). Optimizing DSA parameters for enhanced radiation safety in interventional surgery. Frontiers in Public Health, 13, 1531240.

Sailer, A. M., Vergoossen, L., Paulis, L., van Zwam, W. H., Das, M., Wildberger, J. E., et al. (2017). Personalized feedback on staff dose in fluoroscopy-guided interventions: a new era in radiation dose monitoring. Cardiovascular and Interventional Radiology, 40(11), 1756-1762.

Fujibuchi, T. (2025). Study on Radiation Protection Educational Tool Using Real-Time Scattering Radiation Distribution Calculation Method with Ray Tracing Technology. Information, 16(4), 266.

Wilson, R. F., Steege, P., Riley, R. F., Gomez-Cardona, D., Golduber, R., & Kamen, J. (2026). Reproducibility and Correlation of X-Ray Meters for Monitoring Scatter Radiation During Fluoroscopic Procedures. Health Physics, 130(5), 625-632.

Meisinger, Q. C., Stahl, C. M., Andre, M. P., Kinney, T. B., & Newton, I. G. (2016). Radiation protection for the fluoroscopy operator and staff. American Journal of Roentgenology, 207(4), 745-754.

Haqqani, O. P., Agarwal, P. K., Halin, N. M., & Iafrati, M. D. (2013). Defining the radiation “scatter cloud” in the interventional suite. Journal of vascular surgery, 58(5), 1339-1345.

Downloads

Published

2026-09-19

How to Cite

ÖZDEN, Özcan. (2026). Occupational Radiation Exposure in Diagnostic and Interventional Radiology: A Comprehensive Review. Advances in Medical Pyhsics and Applied Sciences, 2(3), 127–136. https://doi.org/10.63187/ampas.52

Similar Articles

1 2 3 > >> 

You may also start an advanced similarity search for this article.